About Weighing Controller ESS060T
Technical Specification
Standard
- Verification Accuracy: 0.03%.
- Accuracy Grade: III.
- Non-automatic Weighing Instruments International Recommendation.
Display :
- 6+8 Red LED digital tubes for English character and digit display.
- Weight Display Range: -99,999 +999,999.
- Scale Capacity: Setting Range 1999,999.
- Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
- Display Resolution: 1/100,000.
- Weight Unit: Optional kg, t, g, none.
- Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
- Display Refreshing Time: Setting Range 0.01 1.00s.
Kaypad
- 4-key English keypad.
- Menu & Shortcut mode operation with key tone.
Loadcell Interface
- Excitation Voltage/Max. Current: DC9V/120mA 4-350C loadcells.
- Signal Input Range: 0 22.5mV.
- Output Sensitivity of Loadcell: 1.0 2.5mV/V.
- 24-bit ADC with internal resolution 1/1,000,000.
- Sampling Frequency: 400Hz.
- Special anti-vibration digital filtering algorithm.
- Zero Drift: 1/4V RTI (Relative to Input).
- Gain Drift: 5ppm.
- Non-linearity: 0.005%FS.
Switch & Analog Signal Interface
- 6 Normally Open Switch Inputs DI.
- 5 Normally Open Relay Switch Outputs DO: AC250V/DC24V, 1A.
- 1 Optional & Definable Analog Signal Output AO: 4 20mA, Non-linearity: 0.05%FS.
Digital Communication Interface
- COM1: Fixed configuration RS485 & RS232. Free to select one of them via internal dip switch.
- Connectable: Host IPC/PLC and LED Remote Display.
Operating Specification
- Operating Voltage: DC24V+20%.
- Max. Power Consumption: 5W.
- Outline Size: 110-62-150mm W-H-D.
- Panel Cut-out Size: 94-47 mm W-H.
- Operating Temperature: -25to +40
- Storage Temperature: -30 to +60
- Relative Humidity: Max. 85%RH.
- Protection Level of Front Panel: IP65.
- Weight: Approx. 0.5kg.
Specification
|
Country of Origin
|
Made in India
|
|
Weighing Capacity
|
Customised
|
|
Accuracy
|
Class3
|
|
Model Name/Number
|
ESS060[T]
|
|
Input
|
Analog
|
|
Material
|
Stainless Steel
|
|
Brand
|
Esskay
|
|
Voltage
|
240 volt
|
|
Warranty
|
1 year
|
|
Display Type
|
Digital
|
|
Usage/Application
|
Industrial
|
Reliable Automation for Industrial EnvironmentsBuilt for rigorous use, the ESS060T Weighing Controller features robust IP65 protection and operates seamlessly in temperatures ranging from -10C to +60C. Its advanced features, such as overload protection, automatic tare, and up to 6 relay outputs, make it ideal for demanding settings including weighbridges, process control, and batching in industrial automation systems.
Effortless Setup and Flexible OperationWith intuitive front panel keypad programming and support for up to four 350 load cells, configuring the controller to suit specific application requirements is straightforward. The adjustable capacity range and high accuracy (0.02% FS) ensure dependability across a variety of weighing, dosing, or batching tasks, maximizing operational efficiency.
FAQ's of Weighing Controller ESS060T:
Q: How do I program the ESS060T Weighing Controller for specific applications?
A: Programming the ESS060T is performed through its front panel keypad, enabling you to customize parameters for batching, dosing, or weighing tasks. Refer to the user manual for detailed, step-by-step instructions.
Q: What types of industrial environments are suitable for the ESS060T controller?
A: This controller is ideal for industrial automation systems, weighbridges, process control setups, and batching or dosing operations, thanks to its IP65 rating, sturdy ABS body, and wide operating temperature range of -10C to +60C.
Q: What are the benefits of using the ESS060T for batching and process control?
A: The ESS060T offers high-speed response (<100 ms), auto tare, overload protection, and up to 6 relay outputs. These features ensure precise control and automation in batching and process control, reducing manual intervention and enhancing reliability.
Q: How many load cells can the ESS060T accommodate, and what is the excitation voltage?
A: It can connect to up to four load cells, each with 350 impedance, and provides a stable 5V DC excitation voltage to ensure accurate measurement across all connected load cells.
Q: What connectivity options are available with this weighing controller?
A: The ESS060T supports both RS232 and RS485 interfaces for integration with industrial networks or PLCs, as well as relay and wired outputs to facilitate various control and monitoring setups.
Q: Where can the ESS060T be mounted, and what is its power supply requirement?
A: It is designed for panel mounting, and operates on a power supply range of 110-240V AC, 50/60 Hz, with an optional built-in rechargeable battery for uninterrupted operation.